eDART™ System User Guide
Lynx™ Mold-Closed Limit Switch
L-LS
The Lynx™ L-LS Mold-Closed Limit Switch is a tie-bar or
machine mountable machine cycle input module designed to be
used with the eDART System™.
ꢀ
U
The L-LS switch can be used to easily get a machine trigger off of
most injection molding machines by following the installation steps
below.
Always power down before working on
any equipment.
Figure 25: Lynx™ Mold-Closed Limit Switch side view
L-LS Installation
Step 1.
Switch the molding machine to Manual mode and close
the mold.
!
U
Be careful to note the position of the
ejector plate, the mold, the limit switch
and its cable, so the limit switch and/or
its cable does not get caught as the
mold opens and closes.
Step 2.
Set the limit switch on the tie-bar as shown in figures 26
and 27.
Appendix
32
eDART™ System User Guide
Step 4.
Hold the limit switch in place and use a ty-wrap to tighten
it down to the tie-bar. See figure 29.
More than one ty-wrap can be tied together if the tie-bar is
large.
ꢀ
U
B
Always power down before working on
any equipment.
L-LS
A
C
D
Figure 29: Lynx™ Mold-Closed Limit Switch L-LS side view
A
B
C
D
Moving Half
Ejector Plate
Tie Bar
Tighten Ty-Wrap
Table 26: Figure Labels
Step 5.
Plug a Lynx™ cable between the limit switch and the
eDART System™.
Step 6.
Run the machine to ensure proper use, while monitoring
the eDART™ software.
Appendix
34
|
Kuhn Rikon Drill 30 100 User Manual
Lathem GPS Receiver ATX GPS User Manual
Lennox Hearth Stove T150C User Manual
Lindy Car Video System TTX7601 User Manual
Linksys Network Router WRT150N User Manual
Makita Battery Charger DC18SC DC24SA User Manual
Marantz Dust Collector PV5580 User Manual
Melissa Microwave Oven 753 087 User Manual
Memorex DVD Player MVD2045 User Manual
Metrologic Instruments Scanner TECH 7 User Manual